ASTM E 1105-00 (2008) Field Testing
of Installed Windows, Doors and Curtain Walls
for Water Penetration Resistance

RW Olsen   623-824-5232

                                    
 

   

 

                              
ASTM E 1105-00 (2008) "Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference"
 

  
A third party, certified water resistance test is designed to produce a continuous and uniform film of water across the exterior surface of the test specimen. The testing apparatus is calibrated to produce a specific amount of water per square foot, per hour, over the specimen surface area.

 

An interior negative air pressure chamber that simulates the pressure dynamics of a wind-driven rain is constructed and connected to the interior surface of the window-wall interface, then accurately depressurized to meet the Engineering Specification.


ASTM E 783-02 (2010) 
"Standard Test Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors"

This test utilizes the apparatus of the ASTM E 1105 test to accurately depressurize an interior pressure chamber then measure the amount of air infiltration through the specimen.



AAMA 501.2   Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems


Low pressure modifications  to the ASTM E 1105 Test Standard:

AAMA 502-12 "Voluntary Specification for Field Testing of Newly Installed Fenestration Products"

AAMA 503-08 "Voluntary Specification for Field Testing of Newly Installed Storefronts, Curtain Walls and Sloped Glazing Systems"




Independent ASTM field testing assures all stakeholders that installed assemblies are in compliance with product and building specifications.  


  • We use the finest available professional testing equipment  
  • Detailed test reports are produced and presented quickly
  • Accurate, Unbiased and Credible Results
  • ASTM E06.51 committee participant
  • Short-notice nationwide service available
  • Blast Resistant Glazing Systems Specialist
  • Government, Military and Nuclear Facilities Clearance

 

                                          R.W. Olsen
                                      
623-824-5232 

                                                       ray@rwolsen.net

                                  Call today with your technical questions 
                                
                        
 

 

     



Nationwide Service 
 

 
<script type="text/javascript">
var FJHost = ((document.location.protocol == 'https:') ?
 "
https://ssllog." : "http://log.");
document.write(unescape("%3Cscript src='" + FJHost +
 "feedjit.com/pg/fj/5845034a148395d5/'" +
 " type='text/javascript'%3E%3C/script%3E"));
</script>
<script type="text/javascript">
try { var FJ = FJNew(); FJ.logHit(); } catch(err) {}
</script>